DHS & DCS Plate Instrument Set
DHS & DCS Plate Instrument Set
Disponible en stock (99)
No se pudo cargar la disponibilidad de recogida
DHS/DCS Plate Instrument Set
A comprehensive, premium-grade surgical instrument kit engineered specifically for Dynamic Hip Screw (DHS) and Dynamic Condylar Screw (DCS) systems. This set provides high-precision guides, drilling tools, and impactors to ensure accurate alignment and stable fixation for complex proximal and distal femoral fractures.
✨ Core DHS & DCS Advantages
- Enhanced Precision: Specialized tools enable accurate placement of screws and plates, significantly minimizing the risk of malalignment or implant failure.
- Versatility: The set supports the treatment of a wide range of femoral fractures, making it a highly versatile choice for trauma and reconstructive surgeries.
- Reduced Operative Time: The highly organized and efficient nature of the instrument set streamlines surgical workflows, reducing operative time and associated clinical risks.
- Stable Fixation: DHS and DCS systems provide dynamic compression, ensuring rigid fixation and promoting faster fracture healing.
- Minimized Soft Tissue Damage: Supports minimally invasive techniques, reducing trauma to surrounding tissues and enhancing post-operative recovery.
- Durability and Reusability: Crafted from high-quality medical-grade materials to ensure long-term usability, making the set a cost-effective investment for healthcare facilities.
🔬 Treatment of Fracture Types
| Fracture Classification | Clinical Application & System Benefit |
|---|---|
| 01 Intertrochanteric Fractures | DHS systems provide robust and stable fixation for fractures in the proximal femur, reliably restoring patient load-bearing capacity. |
| 02 Subtrochanteric Fractures | The set facilitates the highly accurate placement of implants for complex fractures extending below the lesser trochanter. |
| 03 Distal Femoral Fractures | DCS systems are ideal for stabilizing fractures involving the condyles, ensuring proper anatomical alignment and early joint function. |
| 04 Comminuted Fractures | The instruments allow for secure stabilization of multi-fragmentary fractures, promoting effective and aligned healing. |
| 05 Periprosthetic Fractures | Supports the specialized fixation of fractures occurring around existing implants, such as previous hip or knee prostheses. |
| 06 Pathological Fractures | Highly effective in cases of fractures caused by underlying bone diseases like severe osteoporosis or metastatic tumors, providing reliable mechanical stabilization. |
📦 Instrument Configuration List
| Product Code | Description | Qty |
|---|---|---|
| RQDSBPTKSB | T-handle Quick Coupling | 1 |
| TYTHA45 | Tap Cortical 4.5mm | 1 |
| TYSDZ4565 | Double Drill Sleeve (Φ4.5/Φ6.5) | 1 |
| TYSDZ3245 | Double Drill Sleeve (Φ4.5/Φ3.2) | 1 |
| TYDPSDZ32 | Neutral and Load Drill Guide Φ3.2 | 1 |
| TYTHB65 | Tap Cancellous 6.5mm | 1 |
| TYSZT45180 | Drill Bit Φ4.5 * 180mm | 2 |
| TYSZT32180 | Drill Bit Φ3.2 * 180mm | 2 |
| RQDSCSQ230 | Lag Screw Depth Measuring Device (230mm) | 1 |
| RQDSKZSZ12 | Tap Cancellous 12mm | 1 |
| KSZKL25250 | Threaded K-wire Φ2.5 * 250mm | 3 |
| RQDSDRQ20 | DHS/DCS Impactor Large Φ20 | 1 |
| TYCSC90 | Depth Gauge (0-90mm) | 1 |
| RQDSDRQ9 | DHS/DCS Impactor Small (Φ9) | 1 |
| RQDSQDBS | DHS/DCS Wrench (Purple Sleeve) | 1 |
| RQDSSDBS | DHS/DCS Wrench (Golden Sleeve) | 1 |
| RQDSBKSW35 | Screwdriver Hexagonal 3.5mm | 1 |
| RQDSDWQ95 | DCS Angle Guide 95 Degree | 1 |
| RQDSDWQ135 | DHS Angle Guide 135 Degree | 1 |
| RQDSDHSZT | DHS Reamer | 1 |
| RQDSDCSZT | DCS Reamer | 1 |
| RQDSMJHL | Aluminium Sterilization Box | 1 |
📄 Ordering & Supply Specifications
- Sterilization State: This instrument set (including the aluminium box) is supplied non-sterile. The healthcare facility must strictly clean and autoclave the entire set prior to any surgical intervention according to standard operating protocols.
- Implant Compatibility: Specifically designed to match standard Dynamic Hip Screw (DHS) and Dynamic Condylar Screw (DCS) internal fixation plates and lag screws.
- Instrument Maintenance: Disassemble and thoroughly clean all moving parts immediately post-surgery to prevent blood coagulation and corrosion, ensuring maximum lifespan of the instruments.
⚠️ Clinical Precautions & Regulatory Disclaimer
- Professional Qualification Requirement: This product constitutes a high-risk medical device kit. It must only be operated by qualified, certified orthopedic trauma surgeons within standardized clinical surgical environments.
- Preoperative Assessment: Before utilizing the 135° DHS or 95° DCS angle guides, proper preoperative radiological planning must be conducted to assess the neck-shaft angle and anatomical alignment of the femur.
- Inspection Protocol: Prior to surgical use, inspect the sharpness of the Reamers and the thread integrity of all Taps. Replace immediately if excessive wear is detected to prevent compromising the lag screw's holding power.
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.