INTERTAN Intramedullary Nail Instrument Set
INTERTAN Intramedullary Nail Instrument Set
Disponible en stock (99)
No se pudo cargar la disponibilidad de recogida
INTERTAN Intramedullary Nail Instrument Set Specifications
Product Overview
The INTERTAN Intramedullary Nail Instrument Set is a dedicated surgical instrument system designed for cannulated INTERTAN proximal femoral nail implantation. It supports nail insertion, targeting, proximal interlocking screw placement, compression fixation, distal locking, and final fixation.
Core Specification
| Parameter | Specification |
|---|---|
| Product Name | INTERTAN Intramedullary Nail Instrument Set |
| Compatible Implant System | Cannulated INTERTAN Intramedullary Nail System |
| Compatible Anatomical Location | Proximal Femur |
| Compatible Locking Mechanism | Integrated Interlocking Compression Screw System + Distal Locking Screw Fixation |
| Compatible Nail Type | Cannulated Proximal Femoral INTERTAN Nail |
| Compatible Nail Design | Reconstruction-Type Proximal Femur Nail System |
| Compatible Components | INTERTAN Nail, Screw-I, Screw-II, and Ø4.5 mm Distal Locking Screw |
| Main Function | Nail insertion, targeting, proximal screw placement, fracture compression, distal locking, and implant fixation |
| Instrument Tray | Multi-layer organized instrument tray system |
| Sterilization | Sterilization available upon request |
| Certifications | CE Marked ISO Quality Management System |
Instrument Set Features
- High-Precision Targeting System: Designed according to the INTERTAN implant targeting structure to support accurate intraoperative alignment.
- Integrated Compression Workflow: Supports Screw-I and Screw-II placement for interlocking compression fixation.
- Ergonomic Comfort Design: Silicone handles provide comfortable grip and stable handling during operation.
- Premium Materials & Manufacturing: Stainless steel instruments with professional processing for strength, corrosion resistance, and durability.
Compatible Surgical Application
- INTERTAN intramedullary nail implantation
- Proximal femoral fracture fixation
- Intertrochanteric fracture fixation
- Long nail procedures for selected diaphyseal fracture patterns
- Procedures requiring controlled compression and anti-rotation fixation
Compatible Implant Components
- Cannulated INTERTAN Nail
- Screw-I
- Screw-II
- Ø4.5 mm distal locking screw
- Short and long INTERTAN nail configurations
Instrument Configuration
| Instrument Category | Function |
|---|---|
| Targeting Guide / Aiming Arm | Supports proximal screw targeting and distal locking alignment. |
| Insertion Handle | Assists nail insertion, positioning, and connection with targeting instruments. |
| Drill Sleeves & Guides | Support accurate drilling and screw channel preparation. |
| Screw Placement Instruments | Assist Screw-I and Screw-II placement for interlocking compression fixation. |
| Depth Gauge / Measuring Instruments | Support screw length measurement and intraoperative selection. |
| Screwdrivers | Used for proximal screw and distal locking screw insertion. |
| Extractor / Removal Instruments | Assist implant extraction and revision procedures when required. |
| Instrument Tray / Box | Organized storage for surgical workflow, sterilization, and inventory management. |
Operational Advantages
- Improved Surgical Efficiency: Optimized instrument design helps reduce operation time and simplify workflow.
- Reliable Targeting: Precision targeting design supports stable and repeatable implant positioning.
- Reduced Surgeon Fatigue: Ergonomic handle design improves comfort during prolonged procedures.
- Long Service Life: Durable materials and precision manufacturing support repeated clinical use.
Material & Craftsmanship
- Stainless steel construction for strength, corrosion resistance, and durability.
- Silicone handle design for ergonomic grip.
- Precision machining for stable instrument matching and targeting performance.
- Organized tray system for convenient storage and sterilization management.
Quality & Compliance
- Manufactured under strict medical device quality control requirements.
- CE marked product system.
- ISO quality management system support.
- Designed for repeated clinical workflow and instrument management.
| INTERTAN Intramedullary Nail Instrument Set |
1 | RQZMDSB | Insertion Handle | 1 |
| 2 | RQZMDJDMB | Proximal Aiming Arm | 1 | |
| 3 | RQZMDYDMB | Distal Dynamic Aiming Arm | 1 | |
| 4 | RQZMDDG | Distal Guide Rod for Long Nail | 1 | |
| 5 | RQZMDLJG | Distal Connecting Rod for Long Nail | 1 | |
| 6 | RQZMDYDCWZJ | Distal Location Arm for Long Nail | 1 | |
| 7 | RQZMDLHTT | Combined Sleeve | 1 | |
| 8 | RQZMDLLDCSQ | Depth Gauge for Lag Screw Type II | 1 | |
| 9 | RQZMDLLDDZTT | Guide Wire Sleeve for Lag Screw Type II | 1 | |
| 10 | RQZMDLLDSDQ | Screwdriver for Lag Screw Type II | 1 | |
| 11 | RQZMDLLDSDQNX | Screwdriver Core for Lag Screw Type II, M4.5x0.75 | 1 | |
| 12 | RQZMDLLDTJZ | Open Drill for Lag Screw Type III | 2 | |
| 13 | RQZMDSW45M35 | Hollow Screwdriver for Lag Screw Type III, SW4.5 M3.5x0.6 |
1 | |
| 14 | RQZMD11390JD | Reamer for Lag Screw Type II, φ11*390 | 1 | |
| 15 | RQZMDFXG | Anti-rotation Rod | 1 | |
| 16 | RQZMDDBQ | Impact Rod | 1 | |
| 17 | RQZMDRLZ16320 | Proximal Opening Reamer, φ16*320 | 1 | |
| 18 | RQZMDHCDG | Slide Hammer Guider | 1 | |
| 19 | RQPAWMYSW11 | End Cap Extraction Sleeve | 2 | |
| 20 | RQZMDSW45 | Screwdriver for Polyaxial End Cap, SW4.5 | 1 | |
| 21 | RQZMSDKSW45 | Screwdriver for Hollow Locking Screw, SW4.5 | 1 | |
| 22 | RQZMSDKSW45NX | Suspension Rod for Locking Screw Screwdriver, M3x0.5 | 1 | |
| 23 | RQZMDSW8 | Ball-type Polyaxial Screwdriver, SW8 | 3 | |
| 24 | RQZMDSDTT | Locking Screw Protective Sleeve, φ11/φ8 | 1 | |
| 25 | RQZMDDZ42 | Locking Screw Drill Sleeve, φ8/φ4.2 | 2 | |
| 26 | RQZMDTGZ4 | Locking Screw Trocar, φ4.0 | 1 | |
| 27 | RQZMDZT4340 | Locking Screw Drill Bit, φ4*340 | 1 | |
| 28 | RQZMDSDCSC | Depth Gauge for Locking Screw | 1 | |
| 29 | TYKBSW11 | Open-end Wrench, SW11 | 1 | |
| 30 | RQZMDLSSW8 | Connecting Screw, SW8 M10x1.5 |
1 | |
| 31 | TYJYBS4 | Small Wrench, φ4 | 1 | |
| 32 | RQZMDJSZ | Reduction Rod | 1 | |
| 33 | RQZMDDWG | Location Rod | 1 | |
| 34 | RQZMDDWGZT6 | Location Rod Drill Bit, φ6.0*270 | 1 | |
| 35 | TYTZT6 | Location Rod Drill with Flat-Head, φ6.0 | 1 | |
| 36 | RQZMDTGZ6 | Location Rod Trocar, φ6.0 | 1 | |
| 37 | RQZMDDWGDZ | Location Rod Drill Sleeve | 1 | |
| 38 | RQZMDYM81 | Distal Guide Rod Bolt for Long Nail, M8X1 | 1 | |
| 39 | RQZMDCM61 | Lateral Connecting Bolt, M6X1 | 1 | |
| 40 | RQZMDZHM8125 | Distal Connecting Rod Bolt for Long Nail, M8X1.25 | 1 | |
| 41 | TYQJTZ3510 | Cleaning Guide Wire, φ3.0*510 | 1 | |
| 42 | QD25381000NT | Ball-type Guide Wire | 1 | |
| 43 | TYTDZJCQ | T-Handle Drill Chuck | 1 | |
| 44 | RQZMDHC | Slide Hammer | 1 | |
| 45 | RQZMDTKHSB | T-Handle Quick Coupling | 1 | |
| 46 | KSZL32400 | φ3.2 Threaded Guide Wire,φ3.2*400 | 1 | |
| 47 | RQPAHFB | Tissue Protection Plate | 1 | |
| 48 | RQZMDKHSB | Straight Quick Coupling Handle | 1 | |
| 49 | RQZXYC | Radiopaque Template | 1 | |
| 50 | RQZMDDKDZTT | Multi-holed Guide Wire Sleeve | 1 | |
| 51 | RQZMDRLTT | Protective Sleeve | 1 | |
| 52 | RQZMD4LKZ | Hollow AWL | 1 | |
| 53 | RQZMDLLDSZ | Lag Screw Tap | 2 | |
| 54 | RQZMDZDZT | Drill Bit for Lag Screw Type III | 2 | |
| 55 | RQZMDMJHL | Instrument Box | 1 |
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.