5.5 MIS Spinal System II Pedicle Screw Specifications
Product Overview
The 5.5 MIS Spinal System II Pedicle Screw is designed for minimally invasive thoracolumbar posterior fixation. The system combines a percutaneous screw design, Ø5.5 mm MIS curved rod compatibility, dual-lead non-self-tapping thread design, breakaway nut locking, and dedicated MIS instruments to support stable fixation with reduced surgical exposure.
Core Specifications
| Parameter | Specification |
|---|---|
| Product Name | 5.5 MIS Spinal System II Pedicle Screw |
| Application Site | Thoracolumbar Spine |
| Screw Type | MIS Pedicle Screw |
| Screw Diameter Range | Ø5.0 / Ø5.5 / Ø6.0 / Ø6.5 / Ø7.0 mm |
| Screw Length Range | 25–60 mm |
| Length Increment | 5 mm |
| Thread Design | Dual-Lead Thread |
| Tip Design | Non-Self-Tapping |
| Rod Compatibility | Ø5.5 mm MIS Curved Rod |
| Rod Length Range | 40–120 mm |
| Locking Component | Breakaway Nut |
| Fixation Feature | Anti-loosening fixation with cement augmentation support |
| Material | TC4 Titanium Alloy conforming to GB/T 13810-2017 |
| Surface Treatment | Anodizing, electropolishing, matte / mirror finishing |
| Sterilization | EO Sterile Available |
| Certifications | CE Marked ISO 13485 Medical Devices Quality Management System |
Design Features
- Minimally Invasive Percutaneous Design: Designed for small-incision posterior fixation to reduce surgical exposure and support efficient postoperative recovery.
- Dual-Lead Thread: Dual-thread structure supports stable and controlled screw insertion.
- Non-Self-Tapping Design: Designed for use with dedicated preparation instruments during minimally invasive spinal fixation procedures.
- Anti-Loosening Fixation: Cement augmentation support helps improve fixation strength in osteoporotic bone and reduce loosening risk.
- Mechanical Stability: The bent rod fits tightly with the screw head to support stable force transmission.
- Breakaway Nut Locking: Dedicated locking nut design supports final fixation and system stability.
Clinical Applications
- Thoracolumbar osteoporotic fractures
- Degenerative spinal conditions
- Spinal stenosis
- Spinal tumors
- Implant failure revision
- Revision instability
Core Advantages
- Minimal Bleeding, Fast Recovery: Minimally invasive percutaneous approach with small incision design.
- Anti-Loosening Support: Cement augmentation provides additional fixation support in osteoporotic bone.
- Fluoroscopy-Guided Control: Designed for controlled screw placement under imaging guidance.
Screw Size & Ordering Chart
| REF | Diameter | Length |
|---|---|---|
| R5WIIWZD5025 | Ø5.0 mm | 25 mm |
| R5WIIWZD5030 | Ø5.0 mm | 30 mm |
| R5WIIWZD5035 | Ø5.0 mm | 35 mm |
| R5WIIWZD5040 | Ø5.0 mm | 40 mm |
| R5WIIWZD5045 | Ø5.0 mm | 45 mm |
| R5WIIWZD5050 | Ø5.0 mm | 50 mm |
| R5WIIWZD5055 | Ø5.0 mm | 55 mm |
| R5WIIWZD5060 | Ø5.0 mm | 60 mm |
| R5WIIWZD5525 | Ø5.5 mm | 25 mm |
| R5WIIWZD5530 | Ø5.5 mm | 30 mm |
| R5WIIWZD5535 | Ø5.5 mm | 35 mm |
| R5WIIWZD5540 | Ø5.5 mm | 40 mm |
| R5WIIWZD5545 | Ø5.5 mm | 45 mm |
| R5WIIWZD5550 | Ø5.5 mm | 50 mm |
| R5WIIWZD5555 | Ø5.5 mm | 55 mm |
| R5WIIWZD5560 | Ø5.5 mm | 60 mm |
| R5WIIWZD6025 | Ø6.0 mm | 25 mm |
| R5WIIWZD6030 | Ø6.0 mm | 30 mm |
| R5WIIWZD6035 | Ø6.0 mm | 35 mm |
| R5WIIWZD6040 | Ø6.0 mm | 40 mm |
| R5WIIWZD6045 | Ø6.0 mm | 45 mm |
| R5WIIWZD6050 | Ø6.0 mm | 50 mm |
| R5WIIWZD6055 | Ø6.0 mm | 55 mm |
| R5WIIWZD6060 | Ø6.0 mm | 60 mm |
| R5WIIWZD6525 | Ø6.5 mm | 25 mm |
| R5WIIWZD6530 | Ø6.5 mm | 30 mm |
| R5WIIWZD6535 | Ø6.5 mm | 35 mm |
| R5WIIWZD6540 | Ø6.5 mm | 40 mm |
| R5WIIWZD6545 | Ø6.5 mm | 45 mm |
| R5WIIWZD6550 | Ø6.5 mm | 50 mm |
| R5WIIWZD6555 | Ø6.5 mm | 55 mm |
| R5WIIWZD6560 | Ø6.5 mm | 60 mm |
| R5WIIWZD7025 | Ø7.0 mm | 25 mm |
| R5WIIWZD7030 | Ø7.0 mm | 30 mm |
| R5WIIWZD7035 | Ø7.0 mm | 35 mm |
| R5WIIWZD7040 | Ø7.0 mm | 40 mm |
| R5WIIWZD7045 | Ø7.0 mm | 45 mm |
| R5WIIWZD7050 | Ø7.0 mm | 50 mm |
| R5WIIWZD7055 | Ø7.0 mm | 55 mm |
| R5WIIWZD7060 | Ø7.0 mm | 60 mm |
MIS Curved Rod Options
| Rod Diameter | Length Range | Increment |
|---|---|---|
| Ø5.5 mm | 40–110 mm | 5 mm |
| Ø5.5 mm | 110–120 mm | 10 mm |
Material & Quality
- TC4 titanium alloy conforming to GB/T 13810-2017.
- Qualified for TC4 production with excellent mechanical properties.
- Mechanical tests archived for more than 3 years with full process traceability.
- Quality rate ≥98.9% under strict quality control and improvement system.
Surface & Craftsmanship
- Fine polishing, grinding, and oxidation for consistent color and surface finish.
- CNC turning, milling, and wire EDM processing for precision manufacturing.
- Anodizing, electropolishing, matte and mirror finishing available.
- High-strength joining and accurate fitting of complex components.
Instrument Set
- Compatible with 5.5 MIS Pedicle Screw Instrument Set.
- Dedicated instruments are available for percutaneous screw insertion, rod placement, compression-distraction adjustment, nut locking, and final fixation.
Related Components
| Component | Description |
|---|---|
| Breakaway Nut | Locking component for final fixation. |
| MIS Curved Rod | Ø5.5 mm rod, available in multiple length options. |
| 5.5 MIS Spinal System II Pedicle Screw | Dual-lead non-self-tapping MIS pedicle screw. |
| Compression-Distraction Forceps | Used to compress or distract pedicle screws, correct deformity, restore disc height, and facilitate cage placement. |
| 5.5 MIS Pedicle Screw Instrument Set | Dedicated instrument set for MIS pedicle screw implantation. |
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.